using HybirdFrameworkCore.Autofac.Attribute;
|
|
using HybirdFrameworkDriver.ModbusTcpMaster;
|
|
using HybirdFrameworkDriver.Session;
|
|
using HybirdFrameworkServices.Plc;
|
|
using Service.Init.Entity;
|
|
|
|
namespace Service
|
|
{
|
|
[Scope("SingleInstance")]
|
|
public class EquipmentInit
|
|
{
|
|
/// <summary>
|
|
/// 连接所有数据
|
|
/// </summary>
|
|
/// <exception cref="InvalidOperationException"></exception>
|
|
public void Connect()
|
|
{
|
|
ConnectPlc();
|
|
}
|
|
|
|
/// <summary>
|
|
/// 连接PLC
|
|
/// </summary>
|
|
/// <param name="param"></param>
|
|
/// <returns></returns>
|
|
public int ConnectPlc()
|
|
{
|
|
Thread thread = new Thread(() => ConnectPlcAsync());
|
|
thread.Start();
|
|
|
|
return 0;
|
|
}
|
|
|
|
/// <summary>
|
|
/// 连接PLC
|
|
/// </summary>
|
|
private void ConnectPlcAsync()
|
|
{
|
|
bool connected = false;
|
|
|
|
ModbusTcpMaster master = null;
|
|
//PLC连接
|
|
while (!connected)
|
|
{
|
|
master = new ModbusTcpMaster()
|
|
{
|
|
Ip = "172.0.20.66",
|
|
Port = 502,
|
|
};
|
|
master.ReadAction = BatchReadPlc; //启动线程一直读
|
|
master.Duration = 3000;
|
|
connected = master.Connect();
|
|
|
|
if (connected)
|
|
{
|
|
break;
|
|
}
|
|
|
|
Thread.Sleep(5000);
|
|
}
|
|
|
|
ModbusSession modbusSession = new ModbusSession(master);
|
|
master.connectId = master.Ip + master.Port;
|
|
SessionMgr.RegisterModbusSession(master.connectId, modbusSession);
|
|
SessionMgr.SetAttrModbus(modbusSession, "eqm_sn", 1);
|
|
PlcInfo waterColdInfo = new PlcInfo(master.connectId, 1);
|
|
ChargerStaticInfo.PlcInfos.TryAdd(1, waterColdInfo);
|
|
}
|
|
|
|
/**
|
|
* 一直读
|
|
*/
|
|
private static void BatchReadPlc(ModbusTcpMaster master)
|
|
{
|
|
while (true)
|
|
{
|
|
int sn = 3; //(int)SessionMgr.GetAttrModbus(master.connectId, "eqm_sn");
|
|
|
|
ChargerStaticInfo.PlcInfos.TryGetValue(sn, out PlcInfo plcInfo);
|
|
if (plcInfo != null)
|
|
{
|
|
var bytes01 = master.BatchRead(1, 115);
|
|
if (bytes01 != null)
|
|
{
|
|
ModbusDecoder.Decode<HostToPlc>(bytes01, plcInfo.hostToPlc);
|
|
}
|
|
|
|
var bytes02 = master.BatchRead(201, 222);
|
|
if (bytes02 != null)
|
|
{
|
|
ModbusDecoder.Decode<PlcToHost>(bytes02, plcInfo.plcToHost);
|
|
}
|
|
|
|
var bytes03 = master.BatchRead(701, 10);
|
|
if (bytes03 != null)
|
|
{
|
|
ModbusDecoder.Decode<PlcFault>(bytes03, plcInfo.plcFault);
|
|
}
|
|
//OperateResult<byte[]> result2 = ModbusTcpNet.Read("x=3;201", 222);
|
|
}
|
|
/*
|
|
if (plcInfo != null)
|
|
{
|
|
byte[]? bytes01 = master.BatchRead(0, 22);
|
|
if (bytes01 != null)
|
|
{
|
|
ModbusDecoder.DecodeByT<PlcReadAndWrite2>(bytes01, plcInfo.PlcReadAndWritten2);
|
|
}
|
|
byte[]? bytes02 = master.BatchRead(256, 170);
|
|
if (bytes02 != null)
|
|
{
|
|
ModbusDecoder.DecodeByT<PlcReadonly>(bytes02, plcInfo.PlcReadonly);
|
|
}
|
|
byte[]? bytes03 = master.BatchRead(39424, 108);
|
|
if (bytes03 != null)
|
|
{
|
|
ModbusDecoder.DecodeByT<PlcTurnsRatio>(bytes03, plcInfo.PlcTurnsRatio);
|
|
}
|
|
|
|
byte[]? bytes04 = master.BatchRead(40960, 3);//写编程使能。本机modbus地址。波特率
|
|
byte[]? bytes05 = master.BatchRead(2566, 1);//校验位
|
|
byte[]? bytes06 = master.BatchRead(42, 1);//秒脉冲/无功电能选择
|
|
byte[]? bytes07 = master.BatchRead(48, 1);//电流接线反向
|
|
byte[]? bytes08 = master.BatchRead(4576, 1);//电表清零
|
|
|
|
if (bytes04 != null)
|
|
{
|
|
ModbusDecoder.DecodeByT<PlcReadAndWrite1>(bytes04, plcInfo.PlcReadAndWritten1);
|
|
}
|
|
plcInfo.PlcReadAndWritten1.CheckBit = master.ModbusTcpNet.ByteTransform.TransUInt16(bytes05, 0);
|
|
plcInfo.PlcReadAndWritten1.PulsePerSecond = master.ModbusTcpNet.ByteTransform.TransUInt16(bytes06, 0);
|
|
plcInfo.PlcReadAndWritten1.CurrentReversal = master.ModbusTcpNet.ByteTransform.TransUInt16(bytes07, 0);
|
|
plcInfo.PlcReadAndWritten1.MeterReset = master.ModbusTcpNet.ByteTransform.TransUInt16(bytes08, 0);
|
|
|
|
}
|
|
*/
|
|
}
|
|
}
|
|
}
|
|
} |