using System.Runtime.InteropServices; using Entity.Attr; using HybirdFrameworkCore.Attribute; namespace Entity.Constant; public class InfoEnum { public enum SwapInfo : ushort { [Info("欢迎光临换电站!(正在营业)","欢迎光临换电站!,本站正在营业中")]WelcomeInfo=1, [Info("标签读写失败", "标签读写失败")] ErrorReadRfid , [Info("车辆连接失败", "车辆连接失败,请联系站务人员")] ErrorTBoxConn , [Info("云端校验失败", "云端校验失败,请联系站务人员")] ErrorCloudCheck , [Info("车辆已到位", "车辆已到位")] InfoCarInPosition , [Info("请挂空挡拉手刹", "请挂空挡拉手刹")] ErrorCarInPositionTimeout, [Info("云平台下发换电失败", "云平台下发换电超时")] CloudSendSwapError , [Info("解锁车辆失败", "解锁车辆失败")] ErrUnLockCar , [Info("选包失败,请驶离", "选包失败,请驶离")] ErrorSelectPack , [Info("通道拍照定位失败,请在三分钟内重新调整车辆位置", "通道拍照定位失败,请在三分钟内重新调整车辆位置")]ErrChannelStatus, [Info("亏电电池拆卸中,请稍候", "亏电电池拆卸中,请稍候")] InfoUnPack , [Info("满电电池安装中,请稍候", "满电电池安装中,请稍候")] InfoPack , [Info("电池包已安装完成", "电池包已安装完成")] InfoPackFinish , [Info("堆垛机已回归安全位置", "堆垛机已回归安全位置")] InfoToSafePosition , [Info("换电完成,请将车辆驶出换电站", "换电完成,请将车辆驶出换电站")] InfoCarLeave , [Info("换电失败,请驶离", "换电失败,请驶离")] ErrInfoCarLeave , [Info("亏电池搬运中,请稍候", "亏电池搬运中,请稍候")] InfoOldBatteryCarryIn , [Info("满电电池搬运中,请稍候", "满电电池搬运中,请稍候")] InfoNewBatteryCarryOut , [Info("车辆上锁失败", "车辆上锁失败")] ErrLockCar , [Info("通道的电池仓无可用换电电池","通道的电池仓无可用换电电池")] NoBatteryErr, [Info("结束充电电池数量不足","通道的电池仓无可用换电电池")] LessOfFinishChargingErr, [Info("空仓数量不足","通道的电池仓无可用换电电池")] LessOfEmptyBinErr, [Info("符合soc限制数量不足","通道的电池仓无可用换电电池")] LessOfSocErr, [Info("结束充电大于3分钟的数量不足","通道的电池仓无可用换电电池")] LessOf3MinuteErr, [Info("换电站处于手动模式,不能自动换电","换电站处于手动模式,不能自动换电")] InfoStationModel, [Info("换电站处于本地模式,不能远程换电","换电站处于本地模式,不能远程换电")] InfoStationModelRemoteErr, [Info("请将车辆行驶到指定位置,并拉起手刹","请将车辆行驶到指定位置,并拉起手刹")] CarInInfo, [Info("换电任务启动","换电任务启动")] StartSwapInfo, [Info("相机拍照定位中,请稍后","相机拍照定位中,请稍后")] CarTakePhotoInfo, [Info("启动换电失败,请联系站务人员","启动换电失败,请联系站务人员")] ErrStartSwap, [Info("即将进行消防移仓,请车辆驶离","即将进行消防移仓,请车辆驶离")] InfoFireRemoveLabel, [Info("电池移仓中","电池移仓中")] InfoBatteryMove, [Info("消防移仓中","消防移仓中")] InfoFireRemove, [Info("拍照失败,请在三分钟内挪车","拍照失败,请在三分钟内挪车")] ErrChannel1020, [Info("车辆驶入","车辆驶入")] BeginReadRfid, [Info("请按下一键换电按钮", "请按下一键换电按钮")] ErrStartSwapToTBox , [Info("请将货箱放下", "请将货箱放下")] InfoTboxDown , [Info("请将车辆下电", "请将车辆下电")] InfoTboxEnergyDown , [Info("请将货箱抬起", "请将货箱抬起")] InfoTboxHandUp , [Info("请将车辆上电", "请将车辆上电")] InfoTboxEnergyUp , [Info("通道定位失败,车辆需重新调整位置","通道定位失败,车辆需重新调整位置")] CarTakePhotoErrRepeat, [Info("请操作换电启动按钮","请操作换电启动按钮")] InfoManualStartSwap, [Info("充电机下辅源失败,请人工下辅源","充电机下辅源失败,请人工下辅源")] AuxiliarySource, [Info("加锁成功,请上电降下货箱","加锁成功,请上电降下货箱")] LockSuccess, [Info("开始读取标签","开始读取标签")] BeginRead, [Info("标签读取完成","标签读取完成")] ReadRfid, [Info("开始连接车辆","开始连接车辆")] TboxConnect, [Info("车辆连接完成","车辆连接完成")] CheckTBoxConnectFlag, [Info("开始选包","开始选包")] SelectPack, [Info("充电机下辅源","充电机下辅源")] BeginAuxiliarySource, [Info("下发启动换电","下发启动换电")] StartSwapping, [Info("任务上使能","任务上使能")] HoldOn, [Info("车辆加锁中,请稍候","车辆加锁中,请稍候")] LockCar, } public enum SelectBinStatusInfo : byte { [Const("通道的电池仓无可用换电电池")] NoBattery, [Const("可以换电")] Success, [Const("结束充电电池数量不足")] LessOfFinishCharging, [Const("空仓数量不足")] LessOfEmptyBin, [Const("符合soc限制数量不足")] LessOfSoc, [Const("结束充电大于3分钟的数量不足")] LessOf3Minute, [Const("预约电池异常")] AmtError, } public enum AmtOrderStatus : byte { [Const("预约成功")] Success = 1, [Const("预约取消")] Cancel = 2, [Const("预约失败")] Fail = 3, [Const("换电完成")] SwapFinish = 4, [Const("换电失败")] SwapFail = 5, [Const("换电中")] Swapping = 6, [Const("预约过期")] Expire = 7, } //云平台上报步序 public enum BusinessSwappingForCloudState : byte { [Const("未知")] UnKnown, [Const("空闲")] Idle, [Const("占位")] TakeUp, [Const("换电准备")] SwapReady, [Const("开始换电")] BeginSwap, [Const("换电中")] Swapping, [Const("换电完成")] SwapFinish, [Const("换电中故障,等待修复")] SwappingErrWait, [Const("换电中故障,修复完成")] SwappingErrDone, [Const("换电暂停")] SwapPause, [Const("换电继续")] SwapContinue, [Const("换电完成(车辆未驶离)")] SwapDoneWithVel, [Const("换电完成(车辆驶离)")] SwapDoneWithoutVel } //小步状态 public enum BusinessSwappingStep { [Const("空闲")] Idel, [Const("车辆到站(入口雷达检测到车辆驶入)")] RadarInFlag, [Const("rfid扫描完成")] RfidReadFlag, [Const("车辆到位")] CarInPositionFlag, [Const("换电就绪")] TBoxSwapReadyFlag, [Const("车辆就绪和货箱举升到位")] LowerPressure, [Const("车辆解锁")] VelUnlockFlag, [Const("开始换电")] StartSwappingFlag, [Const("拆旧电池完成")] UnOldBatteryFlag, [Const("入库旧电池完成")] StorageOldBatteryFlag, [Const("搬运新电池完成")] OutNewBatteryFlag, [Const("安装新电池完成")] InstallNewBatteryFlag, [Const("安装完成")] FinishNewBatteryFlag, [Const("车辆上锁")] VelLockFlag, [Const("换电完成(车辆驶离)")] RadarOutFlag, [Const("换电失败(车辆驶离)")] RadarOutFailFlag, } public enum AmtBatLockStatus { UnLock = 0, Lock = 1 } public enum SwapOrderResult : byte { Success = 1, Fail = 2 } }