using HybirdFrameworkCore.Autofac.Attribute;
|
|
|
|
|
|
|
|
|
|
namespace Service.Car.Msg.Car.Req;
|
|
|
|
|
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 温度监测信息
|
|
|
|
|
/// </summary>
|
|
|
|
|
public class TemperatureDetectionMsg
|
|
|
|
|
{
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 故障等级
|
|
|
|
|
/// /// 0:无故障
|
|
|
|
|
/// 1:1 级故障
|
|
|
|
|
/// 2:2 级故障
|
|
|
|
|
/// 3:3 级故障
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248, 8)]
|
|
|
|
|
public byte FaultLevel { get; set; }
|
|
|
|
|
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 换电系统故障码
|
|
|
|
|
/// 0:换电连接器未过温
|
|
|
|
|
///1:换电连接器温度检测 1 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
///2:换电连接器温度检测 2 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
///3:换电连接器温度检测 3 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
///4:换电连接器温度检测 4 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
///5:换电连接器温度检测 5 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
///6:换电连接器温度检测 6 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
///7:换电连接器温度检测 7 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
///8:换电连接器温度检测 8 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
///9:换电连接器温度检测 1 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
///解
|
|
|
|
|
/// 除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
///10:换电连接器温度检测 2 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
///解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
///11:换电连接器温度检测 3 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
///解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
///12:换电连接器温度检测 4 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
///解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
///13:换电连接器温度检测 5 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
///解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
///14:换电连接器温度检测 6 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
///解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
///15:换电连接器温度检测 7 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
///解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
///16:换电连接器温度检测 8 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 0:换电连接器未过温
|
|
|
|
|
/// 1:换电连接器温度检测 1 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
/// 2:换电连接器温度检测 2 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
/// 3:换电连接器温度检测 3 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
/// 4:换电连接器温度检测 4 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
/// 5:换电连接器温度检测 5 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
/// 6:换电连接器温度检测 6 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
/// 7:换电连接器温度检测 7 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
/// 8:换电连接器温度检测 8 过温一级故障
|
|
|
|
|
/// 注:暂不定义一级故障
|
|
|
|
|
/// 9:换电连接器温度检测 1 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 解
|
|
|
|
|
/// 除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
/// 10:换电连接器温度检测 2 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
/// 11:换电连接器温度检测 3 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
/// 12:换电连接器温度检测 4 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
/// 13:换电连接器温度检测 5 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
/// 14:换电连接器温度检测 6 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
/// 15:换电连接器温度检测 7 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
/// 16:换电连接器温度检测 8 过温二级故障
|
|
|
|
|
/// 判定条件:Tmax>90℃,持续 3s;
|
|
|
|
|
/// 解除条件:Tmax<80℃, 持续 3s;
|
|
|
|
|
/// 17:换电连接器温度检测 1 过温三级故障
|
|
|
|
|
/// 判定条件:Tmax>100℃,持续 3s;
|
|
|
|
|
/// 解除条件:需重新上电且 Tmax<70℃, 持续
|
|
|
|
|
/// 3s;
|
|
|
|
|
/// 18:换电连接器温度检测 2 过温三级故障
|
|
|
|
|
/// 判定条件:Tmax>100℃,持续 3s;
|
|
|
|
|
/// 解除条件:需重新上电且 Tmax<70℃, 持续
|
|
|
|
|
/// 3s;
|
|
|
|
|
/// 19:换电连接器温度检测 3 过温三级故障
|
|
|
|
|
/// 判定条件:Tmax>100℃,持续 3s;
|
|
|
|
|
/// 解除条件:需重新上电且 Tmax<70℃, 持续
|
|
|
|
|
/// 3s;
|
|
|
|
|
/// 20:换电连接器温度检测 4 过温三级故障
|
|
|
|
|
/// 判定条件:Tmax>100℃,持续 3s;
|
|
|
|
|
/// 解除条件:需重新上电且 Tmax<70℃, 持续
|
|
|
|
|
/// 3s;
|
|
|
|
|
/// 21:换电连接器温度检测 5 过温三级故障
|
|
|
|
|
/// 判定条件:Tmax>100℃,持续 3s;
|
|
|
|
|
/// 解除条件:需重新上电且 Tmax<70℃, 持续
|
|
|
|
|
/// 3s;
|
|
|
|
|
/// 22:换电连接器温度检测 6 过温三级故障
|
|
|
|
|
/// 判定条件:Tmax>100℃,持续 3s;
|
|
|
|
|
/// 解除条件:需重新上电且 Tmax<70℃, 持续
|
|
|
|
|
/// 3s;
|
|
|
|
|
/// 23:换电连接器温度检测 7 过温三级故障
|
|
|
|
|
/// 判定条件:Tmax>100℃,持续 3s;
|
|
|
|
|
/// 解除条件:需重新上电且 Tmax<70℃, 持续
|
|
|
|
|
/// 3s;
|
|
|
|
|
/// 24:换电连接器温度检测 8 过温三级故障
|
|
|
|
|
/// 判定条件:Tmax>100℃,持续 3s;
|
|
|
|
|
/// 解除条件:需重新上电且 Tmax<70℃, 持续
|
|
|
|
|
/// 3s;
|
|
|
|
|
/// 25:换电连接器温度检测传感器 1 开路二级
|
|
|
|
|
/// 故障
|
|
|
|
|
/// 26:换电连接器温度检测传感器 2 开路二级
|
|
|
|
|
/// 故障
|
|
|
|
|
/// 27:换电连接器温度检测传感器 3 开路二级
|
|
|
|
|
/// 故障
|
|
|
|
|
/// 28:换电连接器温度检测传感器 4 开路二级
|
|
|
|
|
/// 故障
|
|
|
|
|
/// 29:换电连接器温度检测传感器 5 开路二级
|
|
|
|
|
/// 故障
|
|
|
|
|
/// 30:换电连接器温度检测传感器 6 开路二级
|
|
|
|
|
/// 故障
|
|
|
|
|
/// 31:换电连接器温度检测传感器 7 开路二级
|
|
|
|
|
/// 故障
|
|
|
|
|
/// 32:换电连接器温度检测传感器 8 开路二级
|
|
|
|
|
/// 故障
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+8, 8)]
|
|
|
|
|
public byte FaultCode { get; set; }
|
|
|
|
|
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 换电连接器温度检测 1(放电 1正) 有效值-40~210,单位℃
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+2*8, 8)]
|
|
|
|
|
public double ConnectorTemp1 { get; set; }
|
|
|
|
|
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 换电连接器温度检 测 2(放电 1负) 有效值-40~210,单位℃
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+3*8, 8)]
|
|
|
|
|
public double ConnectorTemp2 { get; set; }
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 换电连接器温度检测3(放电2 正) 有效值-40~210,单位℃
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+4*8, 8)]
|
|
|
|
|
public double ConnectorTemp3 { get; set; }
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 换电连接器温度检测 4(放电 2负) 有效值-40~210,单位℃
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+5*8, 8)]
|
|
|
|
|
public double ConnectorTemp4 { get; set; }
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 换电连接器温度检测 5(充电 1正)有效值-40~210,单位℃
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+6*8, 8)]
|
|
|
|
|
public double ConnectorTemp5 { get; set; }
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 换电连接器温度检测 6(充电 1负) 有效值-40~210,单位℃
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+7*8, 8)]
|
|
|
|
|
public double ConnectorTemp6 { get; set; }
|
|
|
|
|
/// <summary>
|
|
|
|
|
/// 换电连接器温度检测 7(充电 2正) 有效值-40~210,单位℃
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+8*8, 8)]
|
|
|
|
|
public double ConnectorTemp7 { get; set; }
|
|
|
|
|
/// <summary>
|
|
|
|
|
///换电连接器温度检测 8(充电 2负) 有效值-40~210,单位℃
|
|
|
|
|
/// </summary>
|
|
|
|
|
[Property(248+9*8, 8)]
|
|
|
|
|
public double ConnectorTemp8 { get; set; }
|
|
|
|
|
}
|