using HybirdFrameworkCore.Autofac.Attribute;
using HybirdFrameworkDriver.ModbusTcpMaster;
using Repository.Station;
using Service.Plc.Msg;
namespace Service.Plc.Client;
///
///
///
[Scope]
public class PlcClient : ModbusTcpMaster
{
private BinInfoRepository _binInfoRepository;
public PlcClient(BinInfoRepository binInfoRepository)
{
ReadAction = BatchRead;
Ip = "172.0.20.66";
Port = 502;
Duration = 2000;
AutoReConnect = true;
_binInfoRepository = binInfoRepository;
}
private void BatchRead(ModbusTcpMaster master)
{
PlcMgr.SendHear();
var bytes01 = master.BatchReadHolderRegister(1, 115);
if (bytes01 != null)
{
PlcMgr.DataValidityTime = DateTime.Now;
ModbusDecoder.Decode(bytes01, PlcMgr.HostToPlcData);
}
var bytes02 = master.BatchReadHolderRegister(201, 222);
if (bytes02 != null)
{
PlcMgr.DataValidityTime = DateTime.Now;
ModbusDecoder.Decode(bytes02, PlcMgr.PlcToHostData);
_binInfoRepository.Update(it => it.Exists == PlcMgr.PlcToHostData.MaterialDetec01.Value, it => it.No == "1");
_binInfoRepository.Update(it => it.Exists == PlcMgr.PlcToHostData.MaterialDetec02.Value, it => it.No == "2");
_binInfoRepository.Update(it => it.Exists == PlcMgr.PlcToHostData.MaterialDetec03.Value, it => it.No == "3");
_binInfoRepository.Update(it => it.Exists == PlcMgr.PlcToHostData.MaterialDetec04.Value, it => it.No == "4");
_binInfoRepository.Update(it => it.Exists == PlcMgr.PlcToHostData.MaterialDetec05.Value, it => it.No == "5");
_binInfoRepository.Update(it => it.Exists == PlcMgr.PlcToHostData.MaterialDetec06.Value, it => it.No == "6");
_binInfoRepository.Update(it => it.Exists == PlcMgr.PlcToHostData.MaterialDetec07.Value, it => it.No == "7");
_binInfoRepository.Update(it => it.Exists == PlcMgr.PlcToHostData.MaterialDetec08.Value, it => it.No == "8");
}
var bytes03 = master.BatchReadHolderRegister(701, 10);
if (bytes03 != null)
{
PlcMgr.DataValidityTime = DateTime.Now;
ModbusDecoder.Decode(bytes03, PlcMgr.PlcFaultData);
}
}
}