Fire alarm, please evacuate
Safety PLC not running
Emergency stop triggered
Main control cabinet emergency stop triggered
Battery swap channel emergency stop triggered
Robot emergency stop triggered
Station control emergency stop triggered
Control room HMI emergency stop triggered
Battery compartment HMI emergency stop triggered
No HMI emergency stop access point selected
Safety door opened
Main control cabinet IO module communication failure
Remote IO module communication failure for hoist
Remote IO module communication failure for robot
Travel into door interference zone alarm, JOG speed max 20
Y-axis encoder runaway
Y-axis encoder communication failure
Y-axis following error alarm
Y-axis encoder failure
X-axis encoder communication failure
Stop after action completed
Battery compartment 1 sensor 1 failure
Battery compartment 2 sensor 1 failure
Battery compartment 3 sensor 1 failure
Battery compartment 4 sensor 1 failure
Battery compartment 5 sensor 1 failure
Battery compartment 6 sensor 1 failure
Battery compartment 7 sensor 1 failure
Battery compartment 8 sensor 1 failure
Battery compartment 1 sensor 2 failure
Battery compartment 2 sensor 2 failure
Battery compartment 3 sensor 2 failure
Battery compartment 4 sensor 2 failure
Battery compartment 5 sensor 2 failure
Battery compartment 6 sensor 2 failure
Battery compartment 7 sensor 2 failure
Battery compartment 8 sensor 2 failure
Entrance radar sensor failure
Exit radar sensor failure
Level 3 alarm triggered, please troubleshoot before continuing
Sliding door opening timeout
Sliding door closing timeout
Not all sliding door opening sensors detected
Both sliding door opening and closing sensors detected
Station preheating not completed, battery swap prohibited
Station heating not completed, battery swap prohibited
Y-axis process object error, PLC restart required
Detected task not completed
Initialization detected battery memory on hoist
X-axis not in standby position
Y-axis not in standby position
Z-axis not in standby position
Hoist pushrod 1 not in standby position
Hoist pushrod 2 not in standby position
Hoist sensor failure
Hoist sensor 1 failure
Hoist sensor 2 failure
Hoist sensor 3 failure
Hoist sensor 4 failure
X-axis position setting error
Y-axis position setting error
Z-axis position setting error
Pushrod not retracted, hoist cannot initialize
Robot current position cannot start transfer task
Robot current position cannot start fire control task
Y-axis recheck sensor failure
Camera program not running
Camera photo timeout
Camera offset value exceeded
Camera photo failed
Y-axis encoder zeroing failed
Anti-loose sensor detected, Z-axis descent restricted
Hoist in place sensor restricting Z-axis descent
System configuration not OK, please configure the system
Station control communication protocol version error
Wire rope 1 slack alarm
Wire rope 2 slack alarm
Wire rope 3 slack alarm
Wire rope 4 slack alarm
X-axis should be within standby position limits
Laser axis origin sensor failure
Y-axis standby position review sensor mismatch
Battery compartment 1 status memory error
Battery compartment 2 status memory error
Battery compartment 3 status memory error
Battery compartment 4 status memory error
Battery compartment 5 status memory error
Battery compartment 6 status memory error
Battery compartment 7 status memory error
Battery compartment 8 status memory error
Z-axis torque exceeded, check if vehicle is unlocked or base is stuck
Main control cabinet IO module not configured alarm
Laser axis not configured alarm
X-axis not configured alarm
Y-axis not configured alarm
X-axis encoder not configured alarm
Station type not configured alarm
Vehicle not entered in the correct direction or exit radar triggered abnormally
Wire rope broken
Control room smoke alarm
Liquid level warning
Liquid level alarm
Wire rope 1 reached total service life, please replace parts
Wire rope 2 reached total service life, please replace parts
Wire rope 3 reached total service life, please replace parts
Wire rope 4 reached total service life, please replace parts
Pushrod 1 reached total service life, please replace parts
Pushrod 2 reached total service life, please replace parts
Spring cable reached total service life, please replace parts
Battery in compartment 1 not placed correctly
Battery in compartment 2 not placed correctly
Battery in compartment 3 not placed correctly
Battery in compartment 4 not placed correctly
Battery in compartment 5 not placed correctly
Battery in compartment 6 not placed correctly
Battery in compartment 7 not placed correctly
Battery in compartment 8 not placed correctly
Battery illegally placed in compartment 1
Battery illegally placed in compartment 2
Battery illegally placed in compartment 3
Battery illegally placed in compartment 4
Battery illegally placed in compartment 5
Battery illegally placed in compartment 6
Battery illegally placed in compartment 7
Battery illegally placed in compartment 8
HMI heartbeat lost
PLC Modbus server command error
Station control heartbeat error
Camera communication error
Device run times reached maintenance warning
Device run times reached maintenance alarm
Wire rope 1 reached service life warning, prepare parts
Wire rope 2 reached service life warning, prepare parts
Wire rope 3 reached service life warning, prepare parts
Wire rope 4 reached service life warning, prepare parts
Pushrod 1 reached service life warning, prepare parts
Pushrod 2 reached service life warning, prepare parts
Spring cable reached service life warning, prepare parts
Wire rope 1 reached maintenance prompt, please maintain
Wire rope 2 reached maintenance prompt, please maintain
Wire rope 3 reached maintenance prompt, please maintain
Wire rope 4 reached maintenance prompt, please maintain
Pushrod 1 reached maintenance prompt, please maintain
Pushrod 2 reached maintenance prompt, please maintain
Spring cable reached maintenance prompt, please maintain
X-axis not torque checked or torque check NG
Y-axis not torque checked or torque check NG
Z-axis not torque checked or torque check NG
Safety door shielded
Idle running
Invalid initialization command received from station control
Valid initialization command received from station control
Invalid start command received from station control
Valid start command received from station control
Invalid reset command received from station control
Valid reset command received from station control
Invalid pause command received from station control
Valid pause command received from station control
Invalid program reset command received from station control
Valid program reset command received from station control
Invalid forced battery swap completion command received from station control
Valid forced battery swap completion command received from station control
Invalid switch to manual mode command received from station control
Valid switch to manual mode command received from station control
Invalid switch to automatic mode command received from station control
Valid switch to automatic mode command received from station control
Invalid switch to remote mode command received from station control
Valid switch to remote mode command received from station control
Invalid switch to local mode command received from station control
Valid switch to local mode command received from station control
Invalid battery swap command received from station control
Valid battery swap command received from station control
Invalid storage command received from station control
Valid storage command received from station control
Invalid retrieval command received from station control
Valid retrieval command received from station control
Invalid warehouse adjustment command received from station control
Valid warehouse adjustment command received from station control
Invalid fire control command received from station control
Valid fire control command received from station control
Remote disconnect transformer command received
Remote disconnect battery swap circuit breaker command received
Remote close all lights command received
Remote close battery swap channel lighting command received
Remote close control room lighting command received
Remote start exhaust fan command received
Invalid battery swap command received from HMI
Valid battery swap command received from HMI
Invalid storage command received from HMI
Valid storage command received from HMI
Invalid retrieval command received from HMI
Valid retrieval command received from HMI
Invalid warehouse adjustment command received from HMI
Valid warehouse adjustment command received from HMI
Invalid fire control command received from HMI
Valid fire control command received from HMI
Safety door not closed properly
HMI emergency stop shielded
Z-axis stopping
Please manually detach the hoist from the battery
Whole station power off triggered
Station control stopping
Station control starting
Station control emergency stopping
Station control alarm resetting
Please lift the battery and move it to the photo position
After manually lifting the battery, press the storage ready OK button
Invalid station start command received from HMI
Invalid station close command received from HMI
Please place the battery in the designated position
Please manually confirm the battery removal OK to complete the removal
Hoist spring line reached warning times
Hoist spring line reached warning times
X-axis standby position setting error
X-axis vehicle guide pick/place position setting error
X-axis photo end position setting error
X-axis vehicle battery pick/place position setting error
X-axis position 1 data setting error
X-axis position 2 data setting error
X-axis position 3 data setting error
X-axis position 4 data setting error
X-axis position 5 data setting error
X-axis position 6 data setting error
X-axis position 7 data setting error
X-axis position 8 data setting error
Y-axis standby position setting error
Y-axis vehicle guide pick/place position setting error
Y-axis photo end position setting error
Y-axis vehicle battery pick position setting error
Y-axis position 1 battery pick/place position setting error
Y-axis position 2 battery pick/place position setting error
Y-axis position 3 battery pick/place position setting error
Y-axis position 4 battery pick/place position setting error
Y-axis position 5 battery pick/place position setting error
Y-axis position 6 battery pick/place position setting error
Y-axis position 7 battery pick/place position setting error
Y-axis position 8 battery pick/place position setting error
Z-axis standby position setting error
Z-axis dynamic vehicle battery pick position setting error
Z-axis vehicle battery pick position setting error
Z-axis ground pick/place position setting error
Z-axis position 1 battery pick/place position setting error
Z-axis position 2 battery pick/place position setting error
Z-axis position 3 battery pick/place position setting error
Z-axis position 4 battery pick/place position setting error
Z-axis position 5 battery pick/place position setting error
Z-axis position 6 battery pick/place position setting error
Z-axis position 7 battery pick/place position setting error
Z-axis position 8 battery pick/place position setting error
Vehicle front/rear direction out of calibration range, please readjust the vehicle
Vehicle left/right direction out of calibration range, please readjust the vehicle
Vehicle angle direction out of calibration range, please readjust the vehicle
Station offline
Submodule error
X-axis servo drive warning
Y-axis servo drive warning
Z-axis servo drive warning
Laser axis servo drive warning
Laser scanning timeout
Laser data acquisition error
Laser width acquisition error
Vehicle angle out of limits, please readjust the vehicle
Vehicle left/right position out of limits, please readjust the vehicle
Vehicle front/rear position out of limits, please readjust the vehicle
Invalid storage command: manual mode
Invalid storage command: not in storage/retrieval process
Invalid storage command: storage compartment must have no battery memory
Invalid storage command: storage compartment sensors must not detect anything
Invalid storage command: hoist material sensors must detect everything
Invalid storage command: X-axis current position must be within channel limits
Invalid storage command: Z-axis must be in standby position
Invalid storage command: incorrect position number entered
Invalid retrieval command: manual mode
Invalid retrieval command: not in storage/retrieval process
Invalid retrieval command: retrieval compartment must have battery memory
Invalid retrieval command: retrieval compartment sensors must detect everything
Invalid retrieval command: hoist material sensors must detect nothing
Invalid retrieval command: hoist must have no battery memory
Invalid retrieval command: incorrect position number entered
Invalid retrieval command: robot must be fully inside the battery compartment
Invalid battery swap command: hoist must have no battery memory
Invalid battery swap command: hoist material sensors must detect nothing
Invalid battery swap command: placing position must have no battery memory
Invalid battery swap command: placing position sensors must detect nothing
Invalid battery swap command: no tasks should be in progress
Invalid battery swap command: must be in local mode
Invalid battery swap command: retrieving position must have battery memory
Invalid battery swap command: retrieving position sensors must detect everything
Invalid battery swap command: retrieving position must have no battery memory
Invalid battery swap command: retrieving position sensors must detect nothing
Invalid transfer command: hoist must have no battery memory
Invalid transfer command: hoist material sensors must detect nothing
Invalid transfer command: retrieving position must have battery memory
Invalid transfer command: retrieving position sensors must detect everything
Invalid transfer command: placing position must have no battery memory
Invalid transfer command: placing position sensors must detect nothing
Invalid transfer command: no tasks should be in progress
Invalid transfer command: must be in local mode
Invalid fire control transfer command: fire handling position must have battery memory
Invalid fire control transfer command: hoist must have no battery memory
Invalid fire control transfer command: hoist material sensors must detect nothing
Invalid fire control transfer command: entry radar not detected
Invalid fire control transfer command: exit radar not detected
Invalid fire control transfer command: no tasks should be in progress
Invalid fire control transfer command: must be in local mode
Preheating conditions not met: X-axis should be enabled
Preheating conditions not met: Y-axis should be enabled
Preheating conditions not met: Z-axis should be enabled
Invalid remote battery swap command: hoist must have no battery memory
Invalid remote battery swap command: hoist material sensors must detect nothing
Invalid remote battery swap command: no tasks should be in progress
Invalid remote battery swap command: must be in remote mode
Invalid remote battery swap command: placing position must have no battery memory
Invalid remote battery swap command: placing position sensors must detect nothing
Invalid remote battery swap command: retrieving position must have battery memory
Invalid remote battery swap command: retrieving position sensors must detect everything
Invalid remote battery swap command: retrieving position must have no battery memory
Invalid remote battery swap command: retrieving position sensors must detect nothing
Invalid remote battery swap command: retrieving position sensors must detect nothing
Invalid remote battery swap command: station control sent incorrect position number
Invalid remote transfer command: hoist must have no battery memory
Invalid remote transfer command: hoist material sensors must detect nothing
Invalid remote transfer command: retrieving position must have battery memory
Invalid remote transfer command: retrieving position sensors must detect everything
Invalid remote transfer command: placing position must have no battery memory
Invalid remote transfer command: placing position sensors must detect nothing
Invalid remote transfer command: no tasks should be in progress
Invalid remote transfer command: must be in remote mode
Invalid remote transfer command: station control sent incorrect position number
Invalid remote fire control transfer command: fire handling position must have battery memory
Invalid remote fire control transfer command: hoist must have no battery memory
Invalid remote fire control transfer command: hoist material sensors must detect nothing
Invalid remote fire control transfer command: entry radar not detected
Invalid remote fire control transfer command: exit radar not detected
Invalid remote fire control transfer command: no tasks should be in progress
Invalid remote fire control transfer command: must be in remote mode
Invalid remote fire control transfer command: station control sent incorrect position number
Single point laser calibration failed
X-axis servo JOG+ interlock alarm
X-axis servo JOG- interlock alarm
X-axis servo positive limit alarm
X-axis servo negative limit alarm
X-axis servo soft limit alarm
X-axis servo communication error
X-axis servo enable lost
X-axis servo home position lost
X-axis mechanical jam or brake not released or circuit error
X-axis external encoder error
X-axis external encoder runaway
X-axis external encoder following error alarm
X-axis servo should be in standby position
X-axis servo should be in vehicle guide pick/place position
X-axis servo should be in vehicle battery standard pick/place position
X-axis servo should be in position 1 battery pick/place position
X-axis servo should be in position 2 battery pick/place position
X-axis servo should be in position 3 battery pick/place position
X-axis servo should be in position 4 battery pick/place position
X-axis servo should be in position 5 battery pick/place position
X-axis servo should be in position 6 battery pick/place position
X-axis servo should be in position 7 battery pick/place position
X-axis servo should be in position 8 battery pick/place position
Y-axis servo JOG+ interlock alarm
Y-axis servo JOG- interlock alarm
Y-axis servo positive limit alarm
Y-axis servo negative limit alarm
Y-axis servo soft limit alarm
Y-axis servo communication error
Y-axis servo enable lost
Y-axis servo home position lost
Y-axis mechanical jam or brake not released or circuit error
Y-axis error (process object); process axis alarm code: %(WATCH1)d process subdivision code: %(WATCH2)d
Y-axis external encoder error
Y-axis external encoder runaway
Y-axis external encoder following error alarm
Y-axis servo should be in standby position
Y-axis servo should be in vehicle guide pick/place position
Y-axis servo should be in vehicle battery standard pick/place position
Y-axis servo should be in position 1 battery pick/place position
Y-axis servo should be in position 2 battery pick/place position
Y-axis servo should be in position 3 battery pick/place position
Y-axis servo should be in position 4 battery pick/place position
Y-axis servo should be in position 5 battery pick/place position
Y-axis servo should be in position 6 battery pick/place position
Y-axis servo should be in position 7 battery pick/place position
Y-axis servo should be in position 8 battery pick/place position
Z-axis servo JOG+ interlock alarm
Z-axis servo JOG- interlock alarm
Z-axis servo lower limit alarm
Z-axis servo upper limit alarm
Z-axis servo soft limit alarm
Z-axis servo communication error
Z-axis servo enable lost
Z-axis servo home position lost
Z-axis mechanical jam or brake not released or circuit error
Z-axis servo should be in standby position
Z-axis servo should be in guide pick/place position
Z-axis servo should be in vehicle battery standard pick/place position
Z-axis servo should be in ground pick/place position
Z-axis servo should be in position 1 battery pick/place position
Z-axis servo should be in position 2 battery pick/place position
Z-axis servo should be in position 3 battery pick/place position
Z-axis servo should be in position 4 battery pick/place position
Z-axis servo should be in position 5 battery pick/place position
Z-axis servo should be in position 6 battery pick/place position
Z-axis servo should be in position 7 battery pick/place position
Z-axis servo should be in position 8 battery pick/place position
Laser servo JOG+ interlock alarm
Laser servo JOG- interlock alarm
Laser servo lower limit alarm
Laser servo upper limit alarm
Laser servo soft limit alarm
Laser servo communication error
Laser servo enable lost
Laser servo home position lost
Laser axis mechanical jam or brake not released or circuit error
Laser servo should be in standby position
Laser servo should be in scan start position
Laser servo should be in scan end position
Y axis error (process object); Process axis alarm code: %(WATCH1)d Process subdivision code: %(WATCH2)d
Laser servo drive anomaly; Drive fault code: %(WATCH1)d
Laser servo process object error; Process axis alarm code: %(WATCH1)d Process subdivision code: %(WATCH2)d
X axis to standby point condition: Z axis in standby position
X axis to standby point condition: No battery on the lifting tool when the car is not completely inside the battery compartment
X axis to vehicle guide pick-and-place position condition: Z axis in standby position
X axis to vehicle battery pick-and-place position condition: Z axis should be in standby position
X axis to vehicle battery pick-and-place position condition: No battery on the lifting tool when the car is not completely inside the battery compartment
X axis to positive channel position condition: Z axis in standby position
X axis to negative channel position condition: Z axis in standby position
X axis to position 1 condition: Z axis in standby
X axis to position 1 condition: Car completely inside the battery compartment
X axis to position 1 condition: Lifting tool has a battery, rack 1 has no battery memory and no induction
X axis to position 1 condition: Lifting tool has a battery, Y axis on rack 1
X axis to position 2 condition: Z axis in standby
X axis to position 2 condition: Car completely inside the battery compartment
X axis to position 2 condition: Lifting tool has a battery, rack 2 has no battery memory and no induction
X axis to position 2 condition: Lifting tool has a battery, Y axis on rack 2
X axis to position 3 condition: Z axis in standby
X axis to position 3 condition: Car completely inside the battery compartment
X axis to position 3 condition: Lifting tool has a battery, rack 3 has no battery memory and no induction
X axis to position 3 condition: Lifting tool has a battery, Y axis on rack 3
X axis to position 4 condition: Z axis in standby
X axis to position 4 condition: Car completely inside the battery compartment
X axis to position 4 condition: Lifting tool has a battery, rack 4 has no battery memory and no induction
X axis to position 4 condition: Lifting tool has a battery, Y axis on rack 4
X axis to position 5 condition: Z axis in standby
X axis to position 5 condition: Car completely inside the battery compartment
X axis to position 5 condition: Lifting tool has a battery, rack 5 has no battery memory and no induction
X axis to position 5 condition: Lifting tool has a battery, Y axis on rack 5
X axis to position 6 condition: Z axis in standby
X axis to position 6 condition: Car completely inside the battery compartment
X axis to position 6 condition: Lifting tool has a battery, rack 6 has no battery memory and no induction
X axis to position 6 condition: Lifting tool has a battery, Y axis on rack 6
X axis to position 7 condition: Z axis in standby
X axis to position 7 condition: Car completely inside the battery compartment
X axis to position 7 condition: Lifting tool has a battery, rack 7 has no battery memory and no induction
X axis to position 7 condition: Lifting tool has a battery, Y axis on rack 7
X axis to position 8 condition: Z axis in standby
X axis to position 8 condition: Car completely inside the battery compartment
X axis to position 8 condition: Lifting tool has a battery, rack 8 has no battery memory and no induction
X axis to position 8 condition: Lifting tool has a battery, Y axis on rack 8
Y axis to standby point condition: Z axis in standby
Y axis to standby point condition: Gantry car completely inside the cabin, X axis in standby position or X axis negative position or X axis positive position or no battery on the lifting tool
Y axis to standby point condition: Gantry car not completely inside the cabin, X axis in standby position or X axis negative position or X axis positive position
Y axis to standby point condition: Sliding door open
Y axis to standby point condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to vehicle guide pick-and-place position condition: Z axis in standby
Y axis to vehicle guide pick-and-place position condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to vehicle guide pick-and-place position condition: Sliding door open
Y axis to vehicle guide pick-and-place position condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to vehicle battery pick-up position condition: Z axis in standby position
Y axis to vehicle battery pick-up position condition: X axis in standby position or X axis negative position or X axis positive position and no battery on the lifting tool
Y axis to vehicle battery pick-up position condition: Sliding door open
Y axis to vehicle battery pick-up position condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to position 1 condition: Z axis in standby
Y axis to position 1 condition: Completely inside the battery compartment, X axis in standby position or X axis negative position or X axis positive position
Y axis to position 1 condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to position 1 condition: Sliding door open
Y axis to position 1 condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to position 2 condition: Z axis in standby
Y axis to position 2 condition: Completely inside the battery compartment, X axis in standby position or X axis negative position or X axis positive position
Y axis to position 2 condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to position 2 condition: Sliding door open
Y axis to position 2 condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to position 3 condition: Z axis in standby
Y axis to position 3 condition: Completely inside the battery compartment, X axis in standby position or X axis negative position or X axis positive position
Y axis to position 3 condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to position 3 condition: Sliding door open
Y axis to position 3 condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to position 4 condition: Z axis in standby
Y axis to position 4 condition: Completely inside the battery compartment, X axis in standby position or X axis negative position or X axis positive position
Y axis to position 4 condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to position 4 condition: Sliding door open
Y axis to position 4 condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to position 5 condition: Z axis in standby
Y axis to position 5 condition: Completely inside the battery compartment, X axis in standby position or X axis negative position or X axis positive position
Y axis to position 5 condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to position 5 condition: Sliding door open
Y axis to position 5 condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to position 6 condition: Z axis in standby
Y axis to position 6 condition: Completely inside the battery compartment, X axis in standby position or X axis negative position or X axis positive position
Y axis to position 6 condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to position 6 condition: Sliding door open
Y axis to position 6 condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to position 7 condition: Z axis in standby
Y axis to position 7 condition: Completely inside the battery compartment, X axis in standby position or X axis negative position or X axis positive position
Y axis to position 7 condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to position 7 condition: Sliding door open
Y axis to position 7 condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Y axis to position 8 condition: Z axis in standby
Y axis to position 8 condition: Completely inside the battery compartment, X axis in standby position or X axis negative position or X axis positive position
Y axis to position 8 condition: X axis in standby position or X axis negative position or X axis positive position
Y axis to position 8 condition: Sliding door open
Y axis to position 8 condition: Lifting tool without battery or lifting tool with battery and laser axis in standby position or start position or end position
Z axis to standby point condition: Push rod fully retracted or extended
Z axis to standby point condition: Current battery not charging
Z axis to dynamic car battery pick-up position condition: XY axes both at guide pick-and-place position or XY axes both at vehicle pick-up position
Z axis to dynamic car battery pick-up position condition: Push rod fully retracted or extended
Z axis to vehicle pick-and-place position condition: XY axes both at guide pick-and-place position or XY axes both at vehicle pick-up position
Z axis to vehicle pick-and-place position condition: Push rod fully retracted or extended
Z axis to ground pick-and-place position condition: XY axes both at guide pick-and-place position or XY axes both at vehicle pick-up position
Z axis to ground pick-and-place position condition: Push rod fully retracted or extended
Z axis to position 1 condition: X axis at rack 1 position
Z axis to position 1 condition: Push rod fully retracted or extended
Z axis to position 1 condition: Y axis at rack 1 position
Z axis to position 2 condition: X axis at rack 2 position
Z axis to position 2 condition: Push rod fully retracted or extended
Z axis to position 2 condition: Y axis at rack 2 position
Z axis to position 3 condition: X axis at rack 3 position
Z axis to position 3 condition: Push rod fully retracted or extended
Z axis to position 3 condition: Y axis at rack 3 position
Z axis to position 4 condition: X axis at rack 4 position
Z axis to position 4 condition: Push rod fully retracted or extended
Z axis to position 4 condition: Y axis at rack 4 position
Z axis to position 5 condition: X axis at rack 5 position
Z axis to position 5 condition: Push rod fully retracted or extended
Z axis to position 5 condition: Y axis at rack 5 position
Z axis to position 6 condition: X axis at rack 6 position
Z axis to position 6 condition: Push rod fully retracted or extended
Z axis to position 6 condition: Y axis at rack 6 position
Z axis to position 7 condition: X axis at rack 7 position
Z axis to position 7 condition: Push rod fully retracted or extended
Z axis to position 7 condition: Y axis at rack 7 position
Z axis to position 8 condition: X axis at rack 8 position
Z axis to position 8 condition: Push rod fully retracted or extended
Z axis to position 8 condition: Y axis at rack 8 position
X axis JOG- condition: Z axis in standby position or JOG speed less than 20
X axis JOG- condition: Push rod retracted or JOG speed less than 50
X axis JOG- condition: Gantry in sliding door area or JOG speed less than 20
X axis JOG- condition: Sliding door open or JOG speed less than 50
X axis JOG+ condition: Z axis in standby position or JOG speed less than 20
X axis JOG+ condition: Push rod retracted or JOG speed less than 50
X axis JOG+ condition: Gantry in sliding door area or JOG speed less than 20
X axis JOG+ condition: Sliding door open or JOG speed less than 50
Y axis JOG- condition: Z axis in standby position or JOG speed less than 20
Y axis JOG- condition: Push rod retracted or JOG speed less than 50
Y axis JOG- condition: Gantry in sliding door area, X axis in safety channel or JOG speed less than 20
Y axis JOG- condition: Sliding door open or JOG speed less than 50
Y axis JOG+ condition: Z axis in standby position or JOG speed less than 20
Y axis JOG+ condition: Push rod retracted or JOG speed less than 50
Y axis JOG+ condition: Gantry in sliding door area, X axis in safety channel or JOG speed less than 20
Y axis JOG+ condition: Sliding door open or JOG speed less than 50
Z axis lift condition: Battery pack charging, lifting battery prohibited
Z axis descent condition: When lifting tool has no battery, material induction must not be detected
Z axis descent condition: Anti-loosening sensor on lifting tool not detected
Laser axis to standby point condition: Lifting tool without battery or lifting tool battery not in the middle of the sliding door
Laser axis to start position condition: Lifting tool without battery or lifting tool battery not in the middle of the sliding door
Laser axis to end position condition: Lifting tool without battery or lifting tool battery not in the middle of the sliding door
Lifter Pusher 1 Jaw Pusher Extension Timeout Alarm
Lifter Pusher 2 Jaw Pusher Extension Timeout Alarm
Lifter Pusher 1 Jaw Pusher Retraction Timeout Alarm
Lifter Pusher 2 Jaw Pusher Retraction Timeout Alarm
Lifter Pusher 1 Jaw Pusher Should Be Extended
Lifter Pusher 2 Jaw Pusher Should Be Extended
Lifter Pusher 1 Jaw Pusher Should Be Retracted
Lifter Pusher 2 Jaw Pusher Should Be Retracted
Lifter Pusher 1 Jaw Pusher Extension Limited
Lifter Pusher 2 Jaw Pusher Extension Limited
Lifter Pusher 1 Jaw Pusher Retraction Limited
Lifter Pusher 2 Jaw Pusher Retraction Limited
Lifter Pusher 1 Jaw Pusher Extension and Retraction Detected Simultaneously
Lifter Pusher 2 Jaw Pusher Extension and Retraction Detected Simultaneously
Lifter Pusher Jaw Pusher Retraction Limited
Lifter Pusher Jaw Pusher Retraction Limited: 2. Wire Rope Should Not Be Under Battery Weight
Lifter Pusher Jaw Pusher Retraction Limited: 3. Lifter Should Have No Battery Memory
Lifter Pusher Jaw Pusher Retraction Limited: 4. Z-axis Should Not Be In Motion
Emergency Stop Button Action Fault
Smoke Sensor Fault
Charging Pile AC Input Circuit Breaker Fault (System Power Supply Circuit Breaker)
DC Bus Positive Output Contactor Refusal/Malfunction Fault
DC Bus Negative Output Contactor Refusal/Malfunction Fault
DC Bus Positive Output Fuse Fault
DC Bus Negative Output Fuse Fault
Charging Interface Electromagnetic Lock Fault
Charging Pile Fan Fault
Surge Protector Fault
Insulation Monitoring Alarm
Battery Polarity Reverse Fault
Vehicle Control Guidance Fault During Charging
Charging Interface Overtemperature Fault
Charging Gun Not In Place Alarm
BMS Communication Fault
Charging Pile Input Overvoltage Fault
Charging Pile Input Undervoltage Fault
DC Bus Output Overvoltage Fault
DC Bus Output Undervoltage Fault
DC Bus Output Overcurrent Fault
Access Control Fault
Positive DC Output Contactor Sticking Fault
Negative DC Output Contactor Sticking Fault
Discharge Circuit Fault
Charging Pile AC Input Contactor Refusal/Malfunction Fault
Charging Pile AC Input Contactor Sticking Fault
Auxiliary Power Supply Fault
Module Output Reverse Fault
Charging Gun Overtemperature Alarm
Charging Pile Overtemperature Alarm
Electric Meter Communication Abnormal
Electric Meter Power Abnormal
Water Immersion Alarm
Reverse Power Alarm
Single Battery Voltage Below Lower Limit
Single Battery Voltage Above Upper Limit
Input Voltage Too High; Main Unit Input Voltage Too High
Input Voltage Too Low; Main Unit Input Voltage Too Low
MCU Voltage Too High; Main Unit MCU Voltage Too High
MCU Voltage Too Low; Main Unit MCU Voltage Too Low
Backup Power Undervoltage
System Running Abnormal; Main Unit Program Running Abnormal
Storage Read/Write Abnormal; Main Unit Storage System Cannot Read/Write Properly
Hardware Fault; Device IC Components (Non-Sensor) Fault
Sensor Fault; Device Sensor Fault
Offline Fault; Main Unit and Device Communication Lost
Fire Extinguisher Feedback Fault; Fire Extinguisher Feedback Detected When Not Activated
Fire Extinguisher Activation Failure; No Activation Current and Voltage Detected When Fire Extinguisher Activated
Fire Extinguisher Activation No Feedback; No Fire Extinguisher Feedback Detected After Activation
Communication Fault; Detector Offline
Main Power Fault; 220V Power Supply Abnormal
Backup Power Fault; Lead-Acid Battery Power Supply Abnormal
Loop Fault; Alarm Two-Wire Loop Short Circuit
Component Fault; Relay Module Fault
Input Fault; Module Input Line Fault
Output Fault; Module Output Line Fault
Maze Cleaning Fault; Detector Maze Needs Cleaning
24V Output Fault; Loop Board 24V Output Fault
Sound and Light Short Circuit Fault; Sound and Light Device Short Circuit Fault
Sound and Light Open Circuit Fault; Sound and Light Device Open Circuit Fault
System Fault; System Fault Detection Test
Loop Board Communication Fault; Main Board and Loop Board Communication Abnormal
Light Key Board Communication Fault; Main Board and Light Key Board Communication Abnormal
Control Panel Communication Fault; Main Board and Expansion Board Communication Abnormal
Gas Extinguishing Loop Fault; Gas Extinguishing Two-Wire Loop Short Circuit
Light Source Fault; Gas Release Alarm Fault
Pressure Switch Open Circuit Fault; Loop Board YK+YK- Open Circuit Fault
Solenoid Valve Short Circuit Fault; Loop Board DC+DC- Short Circuit Fault
Solenoid Valve Open Circuit Fault; Loop Board DC+DC- Open Circuit Fault
Sub-Control Valve Fault
Card reader communication failure
AC input contactor failure
Mainboard hardware failure
Charging module communication alarm
Emergency stop failure
Insulation monitoring failure
Insulation equipment communication failure
Input overvoltage
Input undervoltage
Charging module AC input phase loss alarm
DC output overvoltage alarm
DC output undervoltage alarm
DC output overcurrent alarm
Output short circuit anomaly
DC meter communication failure
AC meter communication failure
Insulation monitoring anomaly
BMS communication timeout
Battery reverse connection fault
Battery not connected before charging
Battery pack overvoltage
Connector connection status abnormal in BSM message
Abnormal power down
Charging cabinet controller communication failure
1# output switch off
2# output switch off
Charging gun not returned to position
Charging pile overtemperature fault
Vehicle control guide alarm during charging
AC circuit breaker fault
Charging interface electronic lock failure
Charging gun overtemperature fault
DC output contactor failure
DC bus output fuse failure
Charger fan failure
Charging overcurrent alarm in BSM message
BMS auxiliary power anomaly
Charging connector fault in BST message
Insulation monitoring module failure
High-voltage relay failure in BST message
Emergency charging state
Terminal reset and power on
Waiting for insulation test failure
Precharge failure alarm
Charging current overcurrent
DC bus voltage anomaly alarm during idle
Module group communication failure
Single battery cell voltage too low in BSM message
Single battery cell voltage too high in BSM message
SOC too high in BSM message
Vehicle parameter anomaly
BRO message (0xAA) reception timeout
Charger receiving BMS enable message timeout
Vehicle detection point 2 voltage detection fault in BST message
Other faults in BST message
Overcurrent in BST message (current exceeds demand)
Voltage anomaly in BST message
Energy cannot be transferred
Current mismatch
Discharge circuit fault
Output connector overtemperature fault in BST message
Output connector overtemperature of BMS components in BST message
Connection anomaly with vehicle
Low temperature shutdown alarm
Pre-insulation monitoring DC output contactor outside voltage ≥10V
DC output contactor outside voltage charger minimum output voltage before charging starts
DC output contactor outside voltage > charger maximum output voltage before charging starts
DC output contactor outside voltage differs from communication message battery voltage by ±5% before charging starts
Battery pack overtemperature in BST message
Insulation fault in BST message
Charging telemetry data timeout in billing unit
Emergency charging state reset
Maintenance door open stop charging
Charging gun lock timeout
Reached discharge voltage termination
Reached discharge SOC termination
SOC too low in BSM message
Single cell voltage higher than maximum allowed charging voltage in BMS message
BRM message reception timeout
BRM message data item anomaly (message length error, BMS communication protocol version error, other data errors)
BCP message reception timeout
BCP message data item anomaly (message length error, BMS communication protocol version error, other data errors)
BRO message (0x00) reception timeout
Battery charging demand message (BCL) timeout
Battery charging total status (BCS) timeout
Power battery status information (BSM) timeout
Battery highest allowable charging voltage less than charger minimum output voltage fault
Data validation failure
Charging controller and billing control unit version verification not completed
Charging controller and billing control unit charging parameter issuance not completed
Charging controller service paused (refer to charging service start control)
Charging controller in "working" state
Charging controller in "paused" state
Charging controller not connected to vehicle
Input high voltage circuit breaker fault
Input high voltage contactor failure
Input high voltage contactor sticking fault
Output high voltage contactor failure
Output high voltage contactor sticking fault
Output high voltage fuse failure
Parallel contactor failure
Parallel contactor sticking fault
Charging module failure
Input voltage fault (input overvoltage/undervoltage, AC input phase loss, input overcurrent, etc.)
Output undervoltage fault
Output overvoltage fault
AC input contactor sticking fault
AC input fault (overvoltage, undervoltage, phase loss, overcurrent)
DC output contactor sticking fault
BMS normal stop charging
BMS abnormal stop charging
Charging controller determines BMS other abnormal termination
Battery pack overtemperature in BSM message
Insulation fault in BSM message
DC bus output contactor failure
SOC anomaly
Other charger faults
Overcharge stop charging
Module group output mode switch failure
AC output overvoltage fault
AC output undervoltage fault
AC output overcurrent fault
AC output short circuit fault
Vehicle stops charging
S2 switch operation timeout
Meter period mismatch
Meter clock anomaly
Backend communication failure
Charging terminal stops service
Meter data overflow warning
Meter data overflow fault
No power available
Current sampling mismatch
Platform clock and local deviation too large
Single cell voltage too low minor alarm
Single cell voltage too low general alarm
Single cell voltage too low severe alarm
Single cell voltage too high minor alarm
Single cell voltage too high general alarm
Single cell voltage too high severe alarm
Single cell voltage difference too large minor alarm
Single cell voltage difference too large general alarm
Single cell voltage difference too large severe alarm
Battery temperature too low minor alarm
Battery temperature too low general alarm
Battery temperature too low severe alarm
Battery temperature too high minor alarm
Battery temperature too high general alarm
Battery temperature too high severe alarm
Battery temperature difference too large minor alarm
Battery temperature difference too large general alarm
Battery temperature difference too large severe alarm
SOC too low minor alarm
SOC too low general alarm
SOC too low severe alarm
Discharge current too large minor alarm
Discharge current too large general alarm
Discharge current too large severe alarm
Charging current too large minor alarm
Charging current too large general alarm
Charging current too large severe alarm
Connector positive/negative end temperature too high general alarm
Positive/negative pole temperature too high minor alarm
Positive/negative pole temperature too high general alarm
Main positive relay sticking fault
Main positive relay open circuit fault
Main negative relay sticking fault
Main negative relay open circuit fault
Hardware failure
Power battery system internal communication failure
Battery thermal failure
Other faults